Ultrasonic testing
Ultrasonic angle beam skip distance calculator
Enter the material thickness and the refracted angle, and optionally the sound path of an indication. The calculator returns the skip distances, the leg lengths, and where the indication sits: depth, surface distance and which leg.
Half skip surface distance
22.00mm
Full skip surface distance
43.99mm
One leg sound path
25.40mm
Full V-path
50.80mm
Indication depth
9.00mm
Indication surface distance
15.59mm · leg 1
Advisory result. Provisional until a qualified inspector or engineer verifies it against the governing code edition.
How it works
- 01Half skip surface distance = T tan θ; full skip = 2 T tan θ.
- 02One leg sound path = T / cos θ; the full V-path is twice that.
- 03For an indication at sound path SP: leg = floor(SP / leg length) + 1; depth in leg 1 = SP cos θ, in leg 2 = 2T - SP cos θ.
- 04Surface distance from the exit point = SP sin θ.
Formulas
half skip = T tan θ, full skip = 2 T tan θleg = T / cos θd = SP cos θ (leg 1), 2T - SP cos θ (leg 2)Read before you rely on it
- Angles are refracted angles in the test material, not wedge angles; verify on the calibration block.
- Curved surfaces, cladding and mode conversion change the geometry; these formulas are for flat plate and thick-wall pipe.
- Locating an indication is a screening step; sizing follows the procedure.
Answers
Questions about this calculator
What is skip distance in ultrasonic testing?
The surface distance the beam travels before returning to the scanning surface. Half skip is one bounce off the back wall, T tan θ; full skip is the return to the top surface, 2 T tan θ. It sets how far back the probe scans to cover a weld.
How do I find the depth of an indication?
Multiply the sound path by the cosine of the refracted angle. If that exceeds the thickness the beam is in the second leg and the depth is 2T minus that product.
Why 45, 60 and 70 degrees?
They are the standard shear-wave angles in steel and cover most weld geometries: 45 for thick sections, 60 general, 70 for thin material and shallow bevels.
Does intelliSPEC record the setup?
intelliNDT captures the probe, angle, calibration and indication position with the UT record, so the reader can reconstruct the scan.